Showing posts with label door. Show all posts
Showing posts with label door. Show all posts

Friday, September 27, 2013

Garage Door Closing Circuit Just using Relays

Because I’m old school, I wanted to build a Garage Door Closing circuit without relying on integrated configurations (555 timer etc) to keep it simplistic. The circuit closes the garage door after two minutes with C3 and four minutes with the addition of C2. The timer relay is surprisingly accurate (+/- five seconds). Another feature is to ensure that the garage door actually did close, such as if it’s stopped mid-operation by the user.


Garage Door Closing Circuit Just using Relays

Description:

S3 (magnetic N.C.) is located at the garage door and activates the circuit when the garage door opens.
RL1 is the reset timer. It’s maintained in the “on” position for two minutes by C3 while the trigger capacitor, C4, is charged. RL2 is the conduit, directing C4 to either RL3 or R1 to ground when off. Purpose of R1 is to prevent arching across contacts and a fast discharge. RL3’s contacts are connected to the Garage Door’s Momentary Switch and is sustained “on”  for a half second by C5.

When C3 discharges to the cutoff voltage of RL1, it turns off and resets. C4 charges C5, which turns on RL3 and initiates the garage door. Because C4 does not have the time to fully discharge, it should be at least three times the value of C5. If it does not close, RL1 in countdown mode will reset and open the door. When it resets again, the door will close.

Turning off the circuit, C1 maintains RL1 “on” slightly longer to ensure that RL2 is set to discharge C4 to R1. If this is not done and C4 is not discharged, the garage door will not open until it discharges naturally and falls below the trigger voltage for RL3.  The circuit would be useless for several days.

Garage Door Closing Circuit Just using Relays

Notes:
  • Time delay of RL1 after reset drops 15 seconds because of the short charge time.
  • To boost RL3 to a one-second delay, increase C5 to 1000uF.
  • D2, D3, and D4 isolate the crucial sections of the circuit.
  • Relays do not turn off at the same rate. I conducted a test by tripping the circuit on and off at a high rate and discovered the possibility of C4 turning on RL3. The addition of C1 solved this.
Author: Roland Segers email@:speedmail-at-gmail.com
Continue reading...

Tuesday, September 10, 2013

Electronic Security Door Key Circuit Diagram

A different Electronic Security Door Key Circuit Diagram of electronic lock very simple, one and does not need a lot of materials in order to it is manufactured. The right keys of code should be stepped with the right line, so that is activated the optocupler IC2. If from error is stepped switch that does not belong in the combination, then the lock is trapped. In order to we restore the regular operation of lock, it should we press switches S1 or S12. 

Read : Heat Detector Alarm using UM3561 

 Electronic Security Door Key Circuit Diagram

Electronic Security Door Key Circuit Diagram


Switch S1 makes Reset of lock externally and the S12 internally, the door. The Code the circuit as he is connected it is 147 and it can change, very easily, changing the connections in the switches of keyboard. The optocupler IC2, can drive any exterior circuit as Relay etc, ensuring simultaneously electric isolation the two circuits. The circuit can be also supplied from a battery 9V.

Read : Radio Wave Alarm

Part List

    R1-7-9=1Kohm
    R2-3-4-5=100Kohm
    R6 =10Kohm
    R9 =47Kohm
    IC1 = 4066
    IC2 =4N25
    Q1-2=BC550
    S1...11=Push button sw or keyboard
    S12=Push button normal closed
    All resistors is 1/4W 5%
Continue reading...